The GE AMX 4 is a classic, battery-powered portable X-ray system designed for dependable radiographic imaging wherever patients need care. Operating entirely from an onboard rechargeable battery pack, the AMX 4 delivers full-power exposures without requiring a wall outlet, making it ideal for ICUs, CCUs, emergency rooms, ORs, orthopedic suites, clinics, pediatric and neonatal units. This system features the MX-75, 275 kHU X-ray tube with a 0.75 mm focal spot, combined with a GE AMX-IV collimator for reliable, high-quality imaging across a wide range of procedures. Variable forward and reverse drive speeds and its fully mobile design allow technologists to position the unit quickly and safely at the bedside. With 24 kVp stations, 30 mAs stations, and consistent 100 mA output, the AMX 4 provides flexible technique selection to meet diverse clinical demands. An LED display and intuitive controls further enhance usability in busy hospital environments.
Key Features
- Battery-operated portable X-ray system
- MX-75 275 kHU X-ray tube with 0.75 mm focal spot
- GE AMX-IV collimator
- High-quality image performance
- Forward and reverse variable speed drive
- Fully mobile, no power connection required for full-power operation
- 24 kVp stations, 30 mAs stations
- 100 mA constant output
- kVp Range: 50–125 kVp
- mAs Range: 0.4–320 mAs
Technical Specifications
| Dimensions | |
|---|---|
| Height | 76 in (1930 mm) |
| Width | 25-3/16 in (640 mm) |
| Depth | 45-3/8 in (1153 mm) |
| Weight | 1050 lb (477 kg) |
| Battery | Nine 12.9 V batteries connected in series (approx. 116 V at full charge) |
| Approximate capacity | 20,000 mAs at 100 kVp under specified conditions |
| Battery | Actual capacity depends on battery condition and use of collimator lamp, electric brakes, rotor, and driving distance |
| Movements (tube vertical movement measured at focal spot) | |
| Vertical Range | At least 52.5 in (1334 mm) |
| Lowest Position | 26.1 in (663 mm) from floor (max) |
| Highest Position | 78.6 in (1996 mm) from floor (min) |
| Horizontal movement at focal spot relative to column face | 24 in (610 mm) min to 40 in (1016 mm) max |
| Tube Column Rotation (from horizontal latch) | 360° |
| Tube and Yoke Rotation around Horizontal Arm (from tube port down) | 360° range; detents at 0°, ±90°, ±180° |
| Tube Trunnion Rotation (from tube port down) | 120° range; forward 110°, backward 10°, detents at 0°, 90° |
| Collimator Rotation (from front with tube port down) | 180° range; right 90°, left 90°, detents at 0°, 90° |
| Drive Speeds | |
| Speed 1 | 264 ft (6705 mm) per minute ±25% (horizontal arm secured) |
| Speed 2 | 30–60% of drive speed (maneuvering speed, arm out of latch) |
| Detail | Drive speed measured on smooth, hard, level surface; reduced on inclines, carpet, or soft surfaces |
| Collimator | Minimum source-to-skin distance >30 cm via skin spacers |
| Collimator | Full 17 in × 17 in (43 cm × 43 cm) radiographic coverage at 40 in (1.02 m) SID |
| Minimum inherent filtration | 2.0 mm Al equivalent at 100 kVp |
| Light Field Intensity | Average illumination at 100 cm (39.37 in) from focal spot ≥ 16 foot-candles (≈170 lux) |