The GE Datex-Ohmeda E-CAiOV Airway Gas Module is an advanced multi-gas monitoring system designed for use with GE anesthesia and compact monitoring systems. Engineered for precision and reliability, the E-CAiOV measures and identifies anesthetic agents, respiratory gases, and patient spirometry parameters directly at the airway—providing comprehensive breath-by-breath data essential for anesthetic management and patient safety. Using Datex-Ohmeda’s proprietary infrared and paramagnetic sensor technologies, the E-CAiOV delivers fast, accurate readings for CO₂, N₂O, O₂, and all five major anesthetic agents (Halothane, Enflurane, Isoflurane, Sevoflurane, and Desflurane). The module integrates seamlessly into the anesthesia workstation, offering real-time waveforms, inspired/end-tidal values, and gas exchange measurements to assist clinicians in maintaining optimal ventilation and anesthesia depth. With its D-fend™ water separation system, compact form factor, and advanced agent identification capabilities, the E-CAiOV provides dependable monitoring for both standard and low-flow anesthesia applications.
Key Features
- [Performance & Design Features] All parameters measured directly in the patient’s airway for true real-time analysis.
- [Performance & Design Features] Datex-Ohmeda D-fendâ„¢ water separation system prevents moisture interference and maintains measurement accuracy.
- [Performance & Design Features] Patient Oxygen Monitoring via paramagnetic technology ensures precise FiOâ‚‚ and EtOâ‚‚ measurement.
- [Performance & Design Features] Integrated Spirometry (Patient Spirometryâ„¢) for direct gas exchange and lung mechanics evaluation.
- [Performance & Design Features] Compact and lightweight module design for flexible installation with GE anesthesia and monitoring systems.
- [Performance & Design Features] Waveform visualization for COâ‚‚, Nâ‚‚O, Oâ‚‚, and anesthetic agent data.
- [Performance & Design Features] Automatic anesthetic agent identification with advanced infrared detection.
- [Key Advantages] Measures and identifies all five anesthetic agents automatically.
- [Key Advantages] Provides comprehensive airway gas and spirometry monitoring in one device.
- [Key Advantages] Offers real-time inspired and end-tidal readings for COâ‚‚, Oâ‚‚, and Nâ‚‚O.
- [Key Advantages] Incorporates high-performance gas sensing with rapid response times (<400 ms).
- [Key Advantages] Designed for compatibility with GE Datex-Ohmeda anesthesia systems, including Aisys, Avance, and Aestiva series.
- [Key Advantages] Compact, modular, and reliable, ideal for clinical environments where accuracy and space efficiency are critical.
Technical Specifications
| Dimensions | |
|---|---|
| Height | 4.4 in (112 mm) |
| Width | 3 in (75 mm) |
| Depth | 9 in (228 mm) |
| Weight | 3.5 lb (1.6 kg) |
| Environmental Conditions | |
| Operating Temperature | +10°C to +40°C |
| Storage Temperature | -25°C to +70°C |
| Atmospheric Pressure | 666 – 1060 hPa (500 – 800 mmHg) |
| Relative Humidity | 10 – 95% non-condensing (0 – 100% condensing in airway) |
| Power | |
| Power Consumption | 12.6 W (average), 14.6 W (momentary) |
| Electrical Safety | Type BF protection |
| COâ‚‚ Measurement (Infrared Technology) | |
| Range | 0 – 15 vol% (0 – 15 kPa / 0 – 113 mmHg) |
| Rise Time | < 400 ms (typical) |
| Accuracy | ± (0.2 vol% + 2% of reading) |
| Cross Gas Effects | < 0.2 vol% (Oâ‚‚, Nâ‚‚O, anesthetic agents) |
| Oâ‚‚ Measurement (Paramagnetic Technology) | |
| Range | 0 – 100 vol% |
| Rise Time | < 400 ms (typical) |
| Accuracy | ± (1 vol% + 2% of reading) |
| Cross Gas Effects | < 1 vol% (anesthetic agents) |
| Cross Gas Effects | < 2 vol% (Nâ‚‚O) |
| Fi–Et Difference Resolution | 0.1 vol% |
| Nâ‚‚O Measurement (Infrared Technology) | |
| Range | 0 – 100 vol% |
| Rise Time | < 400 ms (typical) |
| Accuracy – 0–85% | ± (2 vol% + 2% of reading) |
| Accuracy – >85% | ± (2 vol% + 8% of reading) |
| Cross Gas Effects | < 2 vol% (anesthetic agents) |
| Identifies and measures | Halothane |
| Identifies and measures | Enflurane |
| Identifies and measures | Isoflurane |
| Identifies and measures | Sevoflurane |
| Identifies and measures | Desflurane |
| Identifies and measures | Displays inspired and end-tidal values, waveforms, and concentration differences |
| Respiration Rate | |
| Range | 4 – 60 breaths/min |
| Detection Criteria | 1% variation in COâ‚‚ waveform |